Posted in | Gas Analyzers

Improve Emissions Monitoring with the 410iQ Gas Analyzer

Thermo Scientific iQ Series Gas Analyzers offer round-the-clock access to analyzer data. These analyzers have been designed for capability enhancement over time, thereby reducing troubleshooting duration with a highly accurate and robust solution.

The Thermo Scientific 410iQ Carbon Dioxide Gas Analyzer (CO2 analyzer) delivers equivalent performance in measuring carbon dioxide (CO2) concentration in emissions, employing advanced NDIR optical filter technology.

Experience the continuous intelligence of the iQ Series Gas Analyzer, backed by a two-year warranty. This next-generation platform of gas analyzers offers the following features:

Predictive Diagnostics

Proactively address issues before their emergence by leveraging enhanced serviceability and plug-and-play components. Continuous round-the-clock access to the analyzer's data aids in reducing troubleshooting duration through the use of innovative, interchangeable DMC modules within a highly accurate and robust solution.

Proactive Communications

Ensure optimal performance with iQ360 and email notifications. By subscribing to the iQ360 service, the instrument will directly notify the technical support team when an alarm is triggered. The technical support team will create a corrective action plan and send it to the personnel via email.

Users can avoid unexpected issues and manage the day effectively with the iQ Series Gas Analyzers.

Personal Device Connectivity

Real-time, continuous remote monitoring is achievable through the iQ companion mobile device application. The iQ app facilitates the remote oversight of iQ gas analyzers, provides simplified methods for contacting, and offers immediate access to maintenance alerts as well as product documentation.

Specifications

Source: Thermo Fisher Scientific – Environmental and Process Monitoring Instruments

. .
Certifications/Compliance CE, TUV-SUD Safety, UKCA
Communication Ports Serial ports:
One RS-232/485 port;
One RS-485 external accessory port
Other ports:
Three Full Speed USB ports (one in front, two in rear)
One Gigabit ethernet port
Communication Protocols MODBUS, Streaming, Gesytec (Bayern-Hessen)
Depth (Imperial) 24 in.
Depth (Metric) 609 mm
Description 410iQ Carbon Dioxide Gas Analyzer
Detection Limit 1.0 ppm (60-second averaging time)
Electrical Requirements 100–240 VAC 50/60 Hz, 275 Watts
Height (Imperial) 8.72 in.
Height (Metric) 221.48 mm
Measurement Range 0–10,000 ppm
Outputs Six isolated analog voltages outputs, with four selectable ranges
Six isolated analog current outputs, with two selectable ranges;
Eight solenoid driver outputs
10 Digital reed relay contact outputs
Precision +/- 1.0 % of reading
Span Drift ±2 % of reading (24 hour)
Temperature (Imperial) Operating 41–113 °F
Voltage 100/240 V
Weight (Imperial) 31.3 lb. (standard), 30.1 lb. (high level)
Weight (Metric) 14.2 kg (standard), 13.7 lb. (high level)
Width (Imperial) 16.75 in.
Width (Metric) 424.45 mm
Zero Drift ±1.0 ppm (24 hour)
Detectable Analytes Carbon Dioxide
Flow Rate 1.0 L/min. (1 atm inlet pressure)
Inputs Four Isolated Voltage Inputs 0–10 V, 16 Digital Inputs (TTL)
Linearity ±1.5 % of span (at concentrations of 10–100 % of span)
Response Time 90 seconds (30-second average time)
Temperature (Metric) Operating 5–45 °C
Zero Noise 0.5 ppm RMS (60-second averaging time)
Unit Size Each

Videos

iQ Series of Gas Analyzers: 410iQ Components and Improvements. Video Credit: Thermo Fisher Scientific – Environmental and Process Monitoring Instruments

Thermo Scientific iQ Gas Analyzer Pump Maintenance. Video Credit: Thermo Fisher Scientific – Environmental and Process Monitoring Instruments

Other Equipment by this Supplier

Other Equipment

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.