Posted in | Gas Analyzers

The 48iQ Improves Carbon Monoxide Monitoring In Ambient Air

With a Thermo Scientific iQ Series Gas Analyzer, users can access their analyzer's data around the clock. As an incredibly precise yet durable solution, the iQ Series Gas Analyzers are designed to record and improve over time while cutting down on troubleshooting time.

The Thermo Scientific 48iQ CO monitoring analyzer provides the same performance level to detect carbon monoxide poisoning, while detecting the quantity of CO in ambient air using the gas filter correlation approach.

Overview

Users can take advantage of the iQ Series Gas Analyzers' intelligence, which allows them to foresee and avert problems. The following characteristics are present in Thermo Scientific's next-generation gas analyzer design:

Predictive Diagnostics

Plug-and-play components and improved serviceability aid in preventing issues before they arise. Users can enjoy 24/7 access to their analyzer data while cutting down on troubleshooting time, thanks to the innovative, interchangeable DMC modules in an incredibly precise yet durable method.

Proactive Communications

Email updates and the iQ360 aid in preserving peak performance. When an alert is set off, users who have subscribed to the iQ360 service have direct communication between their device and Thermo Scientific technical support personnel. The technical support staff drafts a correction plan and emails it to the customer's staff.

With the iQ Series Gas Analyzers, users can take charge of their day and avoid surprises.

Personal Device Connectivity

Real-time, continuous remote monitoring is now made possible with the iQ companion mobile device app. The iQ app provides instant access to maintenance updates and product documentation, simple ways to communicate with users, and remote monitoring of iQ gas analyzers.

Video Credit: Thermo Fisher Scientific – Environmental and Process Monitoring Instruments

Specifications

Source: Thermo Fisher Scientific – Environmental and Process Monitoring Instruments

. .
Certifications/Compliance CE, TUV-SUD Safety, RFCA-0981-054, UKCA
Communication Ports Serial Ports:
One RS-232/485 port 1
RS-485 external accessory port

Other Ports:
Three full speed USB ports (one in front, two in rear)
One Gigabit ethernet port
Communication Protocols MODBUS, streaming
Depth (Imperial) 24 in.
Depth (Metric) 609 mm
Description 48iQ Carbon Monoxide Analyzer
Detection Limit 0.04 ppm (30-second averaging time)
Electrical Requirements 100–240 VAC 50/60 Hz 275 Watts
Height (Imperial) 8.72 in.
Height (Metric) 221.48 mm
Measurement Range 0– 10,000 (ppm or mg/m3)
Outputs Six isolated analog voltages outputs, with four selectable ranges
Six isolated analog current outputs, with two selectable ranges; 10 Digital reed relay contact outputs
Eight solenoid driver outputs
Precision +/-0.1 ppm
Span Drift ±0.5 % full scale (24 hour)
Temperature (Imperial) Operating 41–113 °F
Weight (Imperial) 34.3 lb.
Weight (Metric) 15.6 kg
Width (Imperial) 16.75 in.
Width (Metric) 424.45 mm
Zero Drift <0.1 ppm (24 hour)
Detectable Analytes Carbon Monoxide
Flow Rate 1.0 L/min. (1 atm inlet pressure)
Inputs Four Isolated Voltage Inputs 0–10 V, 16 Digital Inputs (TTL)
Linearity ±1 % full scale <1000 ppm; ±2.5 % full scale >1000 ppm
Response Time 60 seconds (30-second average time)
Temperature (Metric) Operating 5–45 °C
Zero Noise 0.02 ppm RMS (30-second averaging time)
Unit Size Each

Other Equipment by this Supplier

Other Equipment

While we only use edited and approved content for Azthena answers, it may on occasions provide incorrect responses. Please confirm any data provided with the related suppliers or authors. We do not provide medical advice, if you search for medical information you must always consult a medical professional before acting on any information provided.

Your questions, but not your email details will be shared with OpenAI and retained for 30 days in accordance with their privacy principles.

Please do not ask questions that use sensitive or confidential information.

Read the full Terms & Conditions.